Microscope opératoire ophtalmique portable

Dimanche, septembre 1, 2019 - 22:54

Surgical and Ophtalmic Microscope SO-111 TZ
Next Generation Ophthalmic Microscope

• Smaller and lighter than ever!
• Lifetime LED light. No bulb failure to interrupt surgery.
• Manual focus and zoom model.
• UV and Blue Light Hazard protection for patient safety.
• Cold light. No harmful infrared.
• Universal AC voltage inputor 12 volt battery.
• Table clamp convenience.

SPECIFICATIONS

OPTICAL HEAD
Viewing System : Binocular stereoscopic, convergent angle 10° for viewing comfort. Image erection by high resolution prism system.
Eyepieces : Tube inclination 45°High field number 22 for wide field of view. High eye relief 24.6mm and reversible eye cups for ease of use by spectacle wearers.
Magnification : Zoom, 4.2x to 25x continuous.
Field of View : 53mm to 9mm depending on magnification.
Working/focal Distance : 170mm from Aux Objective lens.
Refractive Error Correction : ±5D anisometropia
Pupillary Distance : 50mm to 76mm, eyepiece tubes locked for ease of adjustment.
Focusing : Fine focus range ±25mm.
Mould Protection : Anti-fungus pellets (three years protection) standard.

ILLUMINATION
Type : Coaxial, direct optical delivery system.
Lamp : 20W LED, 75,000 lux, lifetime of the microscope.
UV and Blue light hazard : UV and blue light hazard: Filtered to 435nm
Clour Temperature : 3,000°K
Intensity range : Continuous

MOUNTING SYSTEM
Arm : Elbow and angle-poise movement in horizontal and vertical directions. Variable friction locks.
Arm Extension : Vertical pillar to head optical axis, Max. 940mm
Head Tilt : +5° to–45°
Vertical Tension : Adjustable gas spring to set lifting force.
Table Mounting : Left or right side of table.
Clamp : Opening 120mm, throat 160mm
Materials : Anodised aluminium and stainless steel materials are selected to minimise corrosion

POWER SUPPLY
Mains Input : 100-240VAC, 50-60Hz, 2.0A max. @ 100VAC
Mains Output Regulation : < ±5%
Protection : Over voltage, over current and short circuit protection
Battery / Auxiliary Input : 12V DC, polarity and current surge protected.